SREC | |
---|---|
Safety function | In combination wit SR-basic relay: emergency stop monitoring, safety guard monitoring, light grids monitoring |
Certified according to | EN 60204-1; EN ISO 13849-1 ; EN 62061 |
Approvals | CE, TUV, UL |
Supply voltage | AC/DC 24 V / AC 115 V / AC 230 V |
Number of safe relay contacts | 3 |
Max. switching capability of safe relay contacts | 6 A / 250 VAC resistive load |
Number of auxiliary relay contacts | 1 (feedback loop - basic relay) |
Number of non time-delayed contacts | 3 |
Number of time-delayed contacts | - |
Adjustable time delay | - |
Starting behavior | Switches on and of with basic relay |
PL; Cat.; SILCL (EN ISO 13849-1; EN/IEC 62061) | PL e; Cat. 4; SILCL 3 |
Width | 22.5 mm |
Order No. fixed screw terminals | 472182 (24 V) / 472181 (115 V) / 472180 (230 V) |
Order No. plug-in screw terminals | 474182 (24 V) / 474181 (115 V) / 474180 (230 V) |
Order No. push-in twin spring connector | 475182 (24 V) / 475181 (115 V) / 475180 (230 V) |
Order No. EKLS4, set of plug-in screw terminals | 472592 |
Order No. EKLT4; set of push-in twin spring connector | 472595 |